Other information:
Removal
NOTE:
Removal steps in this procedure may contain installation details.
Disconnect the IAT sensor electrical connector.
Loosen the clamp and position aside the air cleaner outlet pipe.
Torque:
44 lb.in (5 Nm)
Release the tab and remove the air cleaner assembly.
Installation
..
Special Tool(s) /
General Equipment
Resistance Spotwelding Equipment
Grinder
Knife
Spot Weld Drill Bit
Locking Pliers
Materials
Name
Specification
Metal Bonding AdhesiveTA-1, TA-1-B, 3M™ 08115, LORD Fusor® 108B, Henkel Teroson EP 5055
-
Seam SealerTA-2-B, 3M™ 08308, LORD Fusor® 803DTM
-
Flex..