Other information:
Removal
NOTE:
Removal steps in this procedure may contain installation details.
Release the retaining tabs and remove the glove compartment.
Disconnect the electrical connector, remove the retainers and the air inlet door actuator.
Installation
To install, reverse the removal p..
B0082:11, B0082:12, B0082:13 and B0082:1A
Refer to Wiring Diagrams Cell 46 for schematic and connector information.
Normal Operation and Fault Conditions
The RCM continuously monitors the passenger safety belt load limiter circuits for the following faults:
Resistance out of range
Unexpected voltage
Short to ground
Faulted passenger safet..