Other information:
Special Tool(s) /
General Equipment
Hog Ring Plier
Removal
WARNING:
The following procedure prescribes critical repair steps
required for correct restraint system operation during a crash. Follow
all notes and steps carefully. Failure to follow step instructions may
result in incorrect operation of the restraint system and increases the
risk of serious pe..
B00D5:11, B00D5:12 and B00D5:13
Refer to Wiring Diagrams Cell 46 for schematic and connector information.
Normal Operation and Fault Conditions
The RCM briefly activates the PAD indicator to prove-out and verify
correct functional operation of the PAD indicator to the occupants.
The RCM monitors the PAD indicator circuits for the following faults:
Open circu..